1000w continue
1200W (30 min)
2400w for surge output
Input voltage
DC 10~15 v
DC 20~30 V
Output voltage
AC 100 V,110 V,120 V,220 V,230 V,240 V
Output voltage
regulation
+/- 5 %
Output waveform
modified sine wave
Output frequency
50 or 60 HZ
Battery low alarm
DC 10+/- 0.5V
DC 21 +/- 0.8 V
Battery low shutdown
DC 9.5 +/- 0.5 V
DC 20 +/- 0.8 V
Standby current
< 0.4 A
< 0.2 A
Charger current
3.5 A
2 A
Transfer time
10m SEC
Efficiency
85~90%
Thermal protect
60 +/- 0.5oC
Cooling
wisdom fan start : when the temperture reach 45oC,
the fan will start automatically
Protections
soft start
output short : shutdown, auto resume after solve short problem
input polarity reverse : by fuse
high voltage input : shutdown
low voltage input : shutdown
overload : shutdown
overtemperture : shutdown
battery low : alarm
intelligent fan control
trouble display : LED
Fuse
30 A * 5
15 A * 5
AC output
three AC outlet (type 1,2)
two AC outlet (the other)